Land Based Genset-JW-WP66 | |
---|---|
Gen-set specifications | |
Model | JW-WP66 |
Standby Rating kVA/kWe | 68.5/55 |
Prime Rating kVA/kWe | 62.5/50 |
Voltage V | 400/230 |
Frequency Hz | 50 |
Power Factor | 0.8(lagging) |
No.of Phases | 3 |
Fuel consumption@25%/50%/75%(Lh) | 4.34/7.12/9.46 |
Fuel consumption@100%/110%(Lh) | 13/14.13 |
Sound@1m(dB * (A)) | Open≤105 dB(A);Silence≤85 dB(A) |
Ambient temp(℃) | -10~45 |
Gen-set regulation class | ISO8528-5 G2 |
Steady-state voltage deviation | ≤±2.5%;≤±5% |
Transient voltage deviation (100% sudden power decrease/increase) | +25%;-20% |
Steady-state frequency band | ≤1.5% |
Transient frequency deviation from rated frequency (100% sudden power decrease/increase) | +12%;-10% |
Genset Model | Prime Rating (kVA) | Length A(mm) | Width B(mm) | Height C(mm) | Wet Weight* (kg) | Standard Fuel tank Capacity (L) |
---|---|---|---|---|---|---|
JW-WP66B1 | 50 | 1930 | 860 | 1218 | 925 | / |
JW-WP66F1 | 50 | 1930 | 860 | 1218 | 1030 | 105 |
JW-WP66L1 | 50 | 2880 | 1050 | 1600 | 1420 | 180 |
Contact Us at Any Time